![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1595893.1 : SL24/LTO - LIB/ERR<80 61 ..... ME: cleaning failed
In this Document
Created from <SR 3-7985140102> Applies to:Sun StorageTek SL24 Tape Autoloader - Version Not Applicable to Not Applicable [Release N/A]HP LTO2 Tape Drive - Version All Versions and later HP LTO3 Tape Drive - Version All Versions and later Information in this document applies to any platform. Symptoms 13.09.25 08:47:15.34 LIB/ERR<80 61 00 25 2B 0F 00 00 00 00 00 00 FF 02 14 FF CauseCleaning of the drive fails and as a result all the backups to the drive fail with various errors like I/O error, read write error etc. SolutionClean the drive using a new or a known good cleaning tape. Perform a test backup with new or known good data tapes and monitor the drive for a couple of days. Attachments This solution has no attachment |
||||||||||||||||
|