Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1594526.1
Update Date:2017-05-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1594526.1 :   SL8500 - Firmware Upgrade, Reboot Appears to Have Hung  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-6984494551>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 After the load and activation of 8.07 version firmware for the SL8500 and the subsequent reboot, there are no LED's lit on the HBC card and the reboot appears to have hung or failed.

Changes

 Upgrading any version of library microcode would trigger this type of event.

Cause

 The HBC card's inability to either read or write to the HBK card caused this problem.

Solution

Service Request must be opened via MOS to have the HBK card replaced.

Replace the HBK card and send back to Colorado via the NCAT system for additional RCA (Root Cause Analysis) until this issue is better understood.

How to Remove / Replace HBK (Security) Card in SL8500 Library:ATR:1490609.1:2 (Doc ID 1490609.1)

419945201 [F] HBK Card, Front of Card Cage, PWA

 

References

<NOTE:1447566.1> - SL8500 - Firmware / Microcode Level Recommendations
<NOTE:1376163.1> - SL8500 - How to Troubleshoot "Servo Mech Track Event" Errors

Attachments