Symptoms
Cause
Solution
References


Created from <SR 3-4794063141>

Applies to:

Sun ZFS Storage 7420 - Version Not Applicable to Not Applicable [Release N/A]
7000 Appliance OS (Fishworks)

Symptoms

Sun 7420 ZFS Storage Appliance


BUI > Maintenance > Hardware showing 256GB of memory  ....  but system actually has 128GB.

Cause

Bug:15684342 - SUNBT7003652 BUI/CLI CAN REPORT INCORRECT INSTALLED MEMORY ON CALLISTO

Solution

Upgrade to an Appliance Firmware Release version containing the fix.

Fixes are available in 2011.1.8.0 and 2013.1.0 or later.

 

References

<BUG:15684342> - SUNBT7003652 BUI/CLI CAN REPORT INCORRECT INSTALLED MEMORY ON CALLISTO