Solution Type  Problem Resolution Sure

Solution  1592959.1 :   Acme Packet: Error 409 When Changing the Configuration  


Related Items
  • Acme Packet 4500
  •  
  • Acme Packet 3820
  •  
  • Net-Net 3810
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Session Delivery Network>SN-SND: Acme Service Provider
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Acme Packet 4500
Net-Net 3810
Acme Packet 3820
Acme Packet OS

Symptoms

 Error 409 when trying to change the configuration.

Cause

When trying to change an object in the configuration, first select it in order to modify it. Below is an example of trying to modify the system-config, without first selecting it.

acme(system-config)# done
error 409 saving system config
acme(system-config)#

acme(system-config)#
acme(system-config)# exit
Save Changes [y/n]?: y
error 409 saving system config
acme(system)#

 

Solution

Here is the same process when first selecting the description field and then changing it:

acme(system-config)# select
acme(system-config)# description test
acme(system-config)# done
system-config
hostname
description test
location
mib-system-contact
mib-system-name
mib-system-location
snmp-enabled enabled
enable-snmp-auth-traps disabled
enable-snmp-syslog-notify disabled
enable-snmp-monitor-traps disabled
enable-env-monitor-traps disabled
snmp-syslog-his-table-length 1
snmp-syslog-level WARNING
system-log-level WARNING
process-log-level NOTICE
process-log-ip-address 0.0.0.0
process-log-port 0
collect
sample-interval 5
push-interval 15
boot-state disabled
start-time now
end-time never
red-collect-state disabled
red-max-trans 1000
red-sync-start-time 5000
red-sync-comp-time 1000
call-trace disabled
internal-trace disabled
log-filter all
default-gateway 10.0.0.0
restart enabled
exceptions
telnet-timeout 0
console-timeout 0
remote-control enabled
cli-audit-trail enabled
link-redundancy-state disabled
source-routing disabled
last-modified-date 2008-12-03 14:44:07
acme(system-config)#

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback