![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1592959.1 : Acme Packet: Error 409 When Changing the Configuration
In this Document
Applies to:Acme Packet 4500Net-Net 3810 Acme Packet 3820 Acme Packet OS SymptomsError 409 when trying to change the configuration. CauseWhen trying to change an object in the configuration, first select it in order to modify it. Below is an example of trying to modify the system-config, without first selecting it. acme(system-config)# done
error 409 saving system config acme(system-config)# acme(system-config)# acme(system-config)# exit Save Changes [y/n]?: y error 409 saving system config acme(system)#
SolutionHere is the same process when first selecting the description field and then changing it: acme(system-config)# select
acme(system-config)# description test acme(system-config)# done system-config hostname description test location mib-system-contact mib-system-name mib-system-location snmp-enabled enabled enable-snmp-auth-traps disabled enable-snmp-syslog-notify disabled enable-snmp-monitor-traps disabled enable-env-monitor-traps disabled snmp-syslog-his-table-length 1 snmp-syslog-level WARNING system-log-level WARNING process-log-level NOTICE process-log-ip-address 0.0.0.0 process-log-port 0 collect sample-interval 5 push-interval 15 boot-state disabled start-time now end-time never red-collect-state disabled red-max-trans 1000 red-sync-start-time 5000 red-sync-comp-time 1000 call-trace disabled internal-trace disabled log-filter all default-gateway 10.0.0.0 restart enabled exceptions telnet-timeout 0 console-timeout 0 remote-control enabled cli-audit-trail enabled link-redundancy-state disabled source-routing disabled last-modified-date 2008-12-03 14:44:07 acme(system-config)#
Attachments This solution has no attachment |
||||||||||||||||
|