Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1588629.1
Update Date:2018-05-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  1588629.1 :   L700 - Drive Cannot Connect to the Correct Speed to Switch  


Related Items
  • Sun StorageTek L700e Tape Library
  •  
  • Sun StorageTek L700 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-7882766923>

Applies to:

Sun StorageTek L700 Tape Library - Version Not Applicable and later
Sun StorageTek L700e Tape Library - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

4GB Tape drives cannot connect to Switch with correct Fibre channel speed.

Changes

 Customer has updated the Switches from 1GB to 4GB.

Cause

 Drives have the wrong Loop ID.

 L700 wrong Loop ID

Solution

 On the Front panel change the Loop ID to 126.

L700 set Loop ID

After this, you will see the correct entry "AUTO"

L700 correct Loop ID


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback