![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1586647.1 : Sun Storage 7000 Unified Storage System: IP MultiPath (IPMP) Group Fails if one of the Links is Disconnected
The NAS Appliance is configured with several Active-Standby IPMP groups. I would expect that these IPMP groups would allow me to disconnect one of the interfaces involved, without losing connectivity. In this Document
Created from <SR 3-7788763998> Applies to:Sun Storage 7410 Unified Storage System - Version All Versions and laterSun Storage 7310 Unified Storage System - Version All Versions and later Sun Storage 7210 Unified Storage System - Version All Versions and later Sun Storage 7110 Unified Storage System - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsThe NAS Appliance is configured with several Active-Standby IPMP groups. CauseNeed to configure link-based detection on the IPMP interface. SolutionSet link-based IPMP. Set the interface addresses to 0.0.0.0 and set the IPMP network IP address to a valid address.
References<NOTE:1396100.1> - Sun Storage 7000 Unified Storage System: Causes and Solutions for Well Known General Networking ProblemsAttachments This solution has no attachment |
||||||||||||||||||
|