Symptoms
Cause
Solution


Created from <SR 3-7840859951>

Applies to:

Sun Server X3-2 - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

Message "Bad PBR Sig" appears during the initial boot process

 

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems

Cause

[SAS:PCIE4:Bus 00-225DD1F5 HITACHI H10906]
  
[SAS:PCIE4:Bus 00-225B1365 HITACHI H10906] -----> O/S installed on second disk.

The output above may differ depending on platform configuration and disk type.

Since the disk which contains the Operating System (O/S) installation is second in the BIOS/UEFI boot priority order, the message "Bad PBR sig" shows during platform initialization as there is not a valid boot record on the first disk in the boot priority order.

 

Solution

Move the OS disk [SAS:PCIE4:Bus 00-225B1365 HITACHI H10906] to Top of the Boot Priority list in BIOS.

This resolves showing of the "Bad PBR sig" message.
 