Asset ID: |
1-72-1580745.1 |
Update Date: | 2017-06-12 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1580745.1
:
SLS6684I RTD rtd_name ON VTSS vtss_name RETURNED ECAM ERROR CC=9 RC=165
Related Items |
- StorageTek Virtual Storage Manager System 6 (VSM6)
- Sun StorageTek Enterprise Library Software (ELS)
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Library Software>SN-TP: MAINSW VTCS
|
In this Document
Created from <SR 3-7709094131>
Applies to:
StorageTek Virtual Storage Manager System 6 (VSM6) - Version All Versions and later
Sun StorageTek Enterprise Library Software (ELS) - Version 7.0 and later
IBM z/OS on System z
Symptoms
Receiving SLS6684I for VRTD address(es) when varying a VSM6 online or offline.
Changes
Removed one or more VRTDs the VTCS CONFIG and VSM6 hardware.
Cause
Although the RTD definitions were removed from the VTCS CONFIG and VSM6, they were not removed from the VLE hardware.
Solution
Open a hardware SR using the VLE serial number so that the FE can be dispatched to verify the VLE hardware configuration and update as needed, ensuring that only the existing VRTDs are defined.
References
<BUG:17381295> - S0C4 ABEND IN SWSVRSP DUE TO REGISTER MISUSE, WITH STORAGE CORRUPTION
Attachments