Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1580745.1
Update Date:2017-06-12
Keywords:

Solution Type  Problem Resolution Sure

Solution  1580745.1 :   SLS6684I RTD rtd_name ON VTSS vtss_name RETURNED ECAM ERROR CC=9 RC=165  


Related Items
  • StorageTek Virtual Storage Manager System 6 (VSM6)
  •  
  • Sun StorageTek Enterprise Library Software (ELS)
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Library Software>SN-TP: MAINSW VTCS
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-7709094131>

Applies to:

StorageTek Virtual Storage Manager System 6 (VSM6) - Version All Versions and later
Sun StorageTek Enterprise Library Software (ELS) - Version 7.0 and later
IBM z/OS on System z

Symptoms

Receiving SLS6684I for VRTD address(es) when varying a VSM6 online or offline.

Changes

Removed one or more VRTDs the VTCS CONFIG and VSM6 hardware.

Cause

Although the RTD definitions were removed from the VTCS CONFIG and VSM6, they were not removed from the VLE hardware.

Solution

Open a hardware SR using the VLE serial number so that the FE can be dispatched to verify the VLE hardware configuration and update as needed, ensuring that only the existing VRTDs are defined.

References

<BUG:17381295> - S0C4 ABEND IN SWSVRSP DUE TO REGISTER MISUSE, WITH STORAGE CORRUPTION

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback