![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1579377.1 : UX:MpCNappl: ERROR: 106: (Events occurred on the network TRAP)
Applies to:Exadata Database Machine V2 - Version All Versions and laterSun Datacenter InfiniBand Switch 36 - Version Not Applicable and later Information in this document applies to any platform. SymptomsUX:MpCNappl: ERROR: 106: ????????????????.(Events occurred on the network TRAP) CauseThe issue is described in the bug CR 6998891 and bug 12687602 - IB Switch Sending False SNMP Trap (IB SNMP LINK TRAP) Solution
This are the false alarm in older switch firmware version SUN DCS 36p version: 1.3.3-2 and can be ignored if it does not occur frequently. We need to upgrade the switch firmware version to latest (2.x family) to fix this issue.
Note :- This SNMP traps can come from any IB port (used or unused port). It does not mean it is specific to single port.
Attachments This solution has no attachment |
||||||||||||
|