Solution Type  Problem Resolution Sure

Solution  1578492.1 :   CELL-07501: How to Check Cell Server Alert Errors  


Related Items
  • Exadata Database Machine X2-2 Qtr Rack
  •  
  • Oracle Exadata Storage Server Software
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-6900875631>

Applies to:

Exadata Database Machine X2-2 Qtr Rack - Version All Versions and later
Oracle Exadata Storage Server Software - Version 11.2.2.4.0 to 11.2.3.2.1 [Release 11.2]
Information in this document applies to any platform.

Symptoms

CELL-07501 errors are reported in your cell server logs.  You would like to verify if these errors are resolved or outstanding.

The CELL-07501 error is usually preceded by another alerthistory update which outlines the problem.  This alerthistory entry may have the "Severity: clear" designation, which means that the underlying issue is now cleared or resolved.

For example you might see in the file /opt/oracle/cell/log/diag/asm/cell/exacel02/trace/ms-odl.trc:

[2012-12-06T14:38:50.515-07:00] [ossmgmt] [NOTIFICATION] [] [ms.core.MSAlertHistory] [tid: 16] [ecid: 172.17.202.61:21361:1333580944821:7,0] AlertHistory 40_2 created. Severity: clear. Message: Flash disk replaced. <exadata:br/>Status : NORMAL <exadata:br/>Manufacturer : MARVELL <exadata:br/>Model Number : SD88SA02 <exadata:br/>Size : 23G <exadata:br/>Serial Number : 1051KL7CYA <exadata:br/>Firmware : D20Y <exadata:br/>Slot Number : PCI Slot: 5; FDOM: 3 <exadata:br/>Cell Disk : FD_15_exacel02 <exadata:br/>Grid Disk : No grid disks exist <exadata:br/>Flash Cache : Present <exadata:br/>Flash Log : Present
[2012-12-06T14:38:50.533-07:00] [ossmgmt] [NOTIFICATION] [CELL-07501] [ms.hwadapter.MSHardwareImpl] [tid: 16] [ecid: 172.17.202.61:21361:1333580944821:7,0] Detected this is appliance type 5.

 

Cause

 CELL-07501 occur frequently in the cell server logs and can cause concern.  

Solution

Use the following commands to determine if there is an issue with the cell server:

 

1.  CellCLI> alter cell validate configuration

A successful output would be:

CellCLI> alter cell validate configuration
Cell exacel02 successfully altered

 

2.  /opt/oracle.SupportTools/CheckSWProfile.sh -c

A successful output would be:

[root@exacel02 ~]# /opt/oracle.SupportTools/CheckSWProfile.sh -c

[INFO] SUCCESS: Meets requirements of operating platform and InfiniBand software.
[INFO] Check does NOT verify correctness of configuration for installed software.

 

If these commands do not return the expected successful outputs, please collect a sundiag report and open a Hardware Request with Support.

MOS Note Oracle Exadata Diagnostic Information required for Disk Failures (Doc ID 761868.1)

References

<NOTE:761868.1> - Oracle Exadata Diagnostic Information required for Disk Failures

Attachments