Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1576194.1
Update Date:2017-09-25
Keywords:

Solution Type  Problem Resolution Sure

Solution  1576194.1 :   SL8500 - FSC 3275 : "Socket Server HandleEvent Call Took Too Long: ReadObjectHandler:LibraryDispatcher xxxx ms"  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
  •  




In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-7643128960>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

3275: "Socket Server handleEvent call took too long: ReadObjectHandler:LibraryDispatcher xxxx ms";

RC3275, FSC3275

Changes

Library was being serviced at the time.
In this particular scenario a suspected opening/disabling of ILC interface was done while the PTP (Pass-Thru-Port) was under maintenance.

Cause

 A timeout occurred on an expected response to an internal library process.

Solution

No action required if this FSC is associated with library maintenace activity.