Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1575072.1
Update Date:2013-09-10
Keywords:

Solution Type  Problem Resolution Sure

Solution  1575072.1 :   Sun Flash F5100 Array: CAM reporting alarm for ESM that "The property Low Battery ... has changed to True"  


Related Items
  • Sun Flash F5100 Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Flash Storage>SN-DK: F5100 F20 Flash
  •  




Created from <SR 3-7647741855>

Applies to:

Sun Flash F5100 Array - Version All Versions and later
Information in this document applies to any platform.

Symptoms

CAM is reporting an alarm for an Energy Storage Module (ESM) within an F5100 array that "The property Low Battery ... has changed to True"

Example : Alarms for ESM2 and ESM3

Alarm ID   : alarm248
Description: The property Low Battery for ESM2 on 508002000046DF00 has changed to True.
Severity   : Major
Element    : ESM2
GridCode   : 86.5.620
Date       : 2013-08-08 10:16:37

Alarm ID   : alarm249
Description: The property Low Battery for ESM3 on 508002000046DF00 has changed to True.
Severity   : Major
Element    : ESM3
GridCode   : 86.5.620
Date       : 2013-08-08 10:16:37

The Expander (EXP) associated with the ESM does not contain any Flash Modules (FMOD).

Example : Both EXP2 and EXP3 contain no FMODs.

disk:EXP2.FMod.00
Status:Removed
disk:EXP2.FMod.01
Status:Removed
disk:EXP2.FMod.02
Status:Removed
disk:EXP2.FMod.03
Status:Removed
disk:EXP2.FMod.04
Status:Removed
disk:EXP2.FMod.05
Status:Removed
disk:EXP2.FMod.06
Status:Removed
disk:EXP2.FMod.07
Status:Removed
disk:EXP2.FMod.08
Status:Removed
disk:EXP2.FMod.09
Status:Removed
disk:EXP2.FMod.10
Status:Removed
disk:EXP2.FMod.11
Status:Removed
disk:EXP2.FMod.12
Status:Removed
disk:EXP2.FMod.13
Status:Removed
disk:EXP2.FMod.14
Status:Removed
disk:EXP2.FMod.15
Status:Removed
disk:EXP2.FMod.16
Status:Removed
disk:EXP2.FMod.17
Status:Removed
disk:EXP2.FMod.18
Status:Removed
disk:EXP2.FMod.19
Status:Removed
disk:EXP3.FMod.00
Status:Removed
disk:EXP3.FMod.01
Status:Removed
disk:EXP3.FMod.02
Status:Removed
disk:EXP3.FMod.03
Status:Removed
disk:EXP3.FMod.04
Status:Removed
disk:EXP3.FMod.05
Status:Removed
disk:EXP3.FMod.06
Status:Removed
disk:EXP3.FMod.07
Status:Removed
disk:EXP3.FMod.08
Status:Removed
disk:EXP3.FMod.09
Status:Removed
disk:EXP3.FMod.10
Status:Removed
disk:EXP3.FMod.11
Status:Removed
disk:EXP3.FMod.12
Status:Removed
disk:EXP3.FMod.13
Status:Removed
disk:EXP3.FMod.14
Status:Removed
disk:EXP3.FMod.15
Status:Removed
disk:EXP3.FMod.16
Status:Removed
disk:EXP3.FMod.17
Status:Removed
disk:EXP3.FMod.18
Status:Removed
disk:EXP3.FMod.19
Status:Removed

Cause

The alarms are expected behavior. As there are no FMODs installed in the associated EXP, the ESM will not be charged and it will persistently report a Low Battery status.


If FMODs are ever installed in either EXP2 or EXP3, then the Charging Status for the associated ESM will change (to "Charging") and the Low Battery status will be cleared.

Solution

As this is normal behavior, no action is needed. Replacing an ESM is not required.