![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1575072.1 : Sun Flash F5100 Array: CAM reporting alarm for ESM that "The property Low Battery ... has changed to True"
Created from <SR 3-7647741855> Applies to:Sun Flash F5100 Array - Version All Versions and laterInformation in this document applies to any platform. SymptomsCAM is reporting an alarm for an Energy Storage Module (ESM) within an F5100 array that "The property Low Battery ... has changed to True" Example : Alarms for ESM2 and ESM3 Alarm ID : alarm248
Description: The property Low Battery for ESM2 on 508002000046DF00 has changed to True. Severity : Major Element : ESM2 GridCode : 86.5.620 Date : 2013-08-08 10:16:37 Alarm ID : alarm249 Description: The property Low Battery for ESM3 on 508002000046DF00 has changed to True. Severity : Major Element : ESM3 GridCode : 86.5.620 Date : 2013-08-08 10:16:37 The Expander (EXP) associated with the ESM does not contain any Flash Modules (FMOD). Example : Both EXP2 and EXP3 contain no FMODs. disk:EXP2.FMod.00
Status:Removed disk:EXP2.FMod.01 Status:Removed disk:EXP2.FMod.02 Status:Removed disk:EXP2.FMod.03 Status:Removed disk:EXP2.FMod.04 Status:Removed disk:EXP2.FMod.05 Status:Removed disk:EXP2.FMod.06 Status:Removed disk:EXP2.FMod.07 Status:Removed disk:EXP2.FMod.08 Status:Removed disk:EXP2.FMod.09 Status:Removed disk:EXP2.FMod.10 Status:Removed disk:EXP2.FMod.11 Status:Removed disk:EXP2.FMod.12 Status:Removed disk:EXP2.FMod.13 Status:Removed disk:EXP2.FMod.14 Status:Removed disk:EXP2.FMod.15 Status:Removed disk:EXP2.FMod.16 Status:Removed disk:EXP2.FMod.17 Status:Removed disk:EXP2.FMod.18 Status:Removed disk:EXP2.FMod.19 Status:Removed disk:EXP3.FMod.00 Status:Removed disk:EXP3.FMod.01 Status:Removed disk:EXP3.FMod.02 Status:Removed disk:EXP3.FMod.03 Status:Removed disk:EXP3.FMod.04 Status:Removed disk:EXP3.FMod.05 Status:Removed disk:EXP3.FMod.06 Status:Removed disk:EXP3.FMod.07 Status:Removed disk:EXP3.FMod.08 Status:Removed disk:EXP3.FMod.09 Status:Removed disk:EXP3.FMod.10 Status:Removed disk:EXP3.FMod.11 Status:Removed disk:EXP3.FMod.12 Status:Removed disk:EXP3.FMod.13 Status:Removed disk:EXP3.FMod.14 Status:Removed disk:EXP3.FMod.15 Status:Removed disk:EXP3.FMod.16 Status:Removed disk:EXP3.FMod.17 Status:Removed disk:EXP3.FMod.18 Status:Removed disk:EXP3.FMod.19 Status:Removed CauseThe alarms are expected behavior. As there are no FMODs installed in the associated EXP, the ESM will not be charged and it will persistently report a Low Battery status.
SolutionAs this is normal behavior, no action is needed. Replacing an ESM is not required. References<BUG:15681104> - SUNBT6999621 ESM ALARM WITH NO FMODS INSTALLED IN EXPANDERAttachments This solution has no attachment |
||||||||||||
|