Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1574646.1
Update Date:2018-03-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  1574646.1 :   VLE Port igb0 Problems  


Related Items
  • Sun Virtual Library Extension (VLE)
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VLE
  •  




In this Document
Symptoms
Changes
Cause
Solution


Applies to:

Sun Virtual Library Extension (VLE) - Version 1.0 to 1.3 [Release 1.0]
Information in this document applies to any platform.

Symptoms

 VLE cannot be brought online to the host.

Changes

 During the install and/or configuration work un-supported actions were performed against the igb0 port.

 These actions might include but not be limited to the deletion of igb0, editing of igb0 using Solaris commands outside of the 'setup_network' script, etc.

Cause

 The igb0 port is central to the VLE's internal communications.
 This port is used for much more than just ASR traffic.
 If the igb0 port altered by means other than those documented in the installation manual there is an extremely high probability that the VLE will not work properly.

Solution

 DO NOT alter the igb0 port configuration by any means other than the running of the 'setup_network' or 'setup_network -dns' script that is part of the initial installation.

 If you believe that a change to the igb0 port is required after the 'setup_network' or 'setup_network -dns' script has been run the first time then contact support for guidance.


Attachments
This solution has no attachment