Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1573398.1
Update Date:2017-02-07
Keywords:

Solution Type  Problem Resolution Sure

Solution  1573398.1 :   Brocade 300 Fabric OS: v6.2.0c NPIV Port Settings Require Switch To Be In AG Mode  


Related Items
  • Brocade 300 Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7611444718>

Applies to:

Brocade 300 Switch - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Customer is trying to enable NPIV on Brocade 300 ports 12 and 13

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk/Tape Storage Area Networks

Cause

Switch state is
switchType: 71.2
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 1
 
Switch state should be AG

switchType: 71.2
switchState: Online
switchMode: Access Gateway Mode
switchWwn: ...
 

Brocade Fabric OS 6.2.0c requirement

Later versions of Fabric OS has NPIV enabled by default , this requirement was only for FOS 6.2.0c or before.

 

Document is no longer valid and should be withdrawn.

 

Solution

Access Gateway (AG)
Fabric OS mode for switches that reduces SAN (storage area network)
deployment complexity by leveraging NPIV (N_Port ID Virtualization).

Per Brocade Access Gateway (AG) Administrator's Guide, the Administrator will be prompted to reboot the Switch whenever enabling or disabling AG and when disabling AG the switchDisable command must be run to disable the switch before the ag --modedisable command is issued.

 
NPIV N_Port ID Virtualization. Allows a single FC_Port to appear as multiple,
distinct ports providing separate port identification and security zoning with
the fabric for each operating system image as if each one had its own
physical port.


Run configUpload - Uploads system configuration data to a file. Recommended if there is a existing switch configuration

 

Enable AG mode
ag --modeenable

To disable
 ag --modeshow --modedisable

To show mode Example
 ag --modeshow
Access Gateway mode is NOT enabled
 

 

See Brocade Access Gateway (AG) Administrators Guide

The Administrator will be prompted to reboot the switch whenever enabling or disabling AG

The switchDisable command must be run to disable the switch before ag --modedisable command is issued

 

 