Created from <SR 3-7611444718> Applies to:Brocade 300 Switch - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsCustomer is trying to enable NPIV on Brocade 300 ports 12 and 13 To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk/Tape Storage Area Networks
CauseSwitch state is Brocade Fabric OS 6.2.0c requirement Later versions of Fabric OS has NPIV enabled by default , this requirement was only for FOS 6.2.0c or before.
Document is no longer valid and should be withdrawn.
SolutionAccess Gateway (AG) Per Brocade Access Gateway (AG) Administrator's Guide, the Administrator will be prompted to reboot the Switch whenever enabling or disabling AG and when disabling AG the switchDisable command must be run to disable the switch before the ag --modedisable command is issued.
Enable AG mode
ag --modeenable To disable ag --modeshow --modedisable To show mode Example ag --modeshow Access Gateway mode is NOT enabled
See Brocade Access Gateway (AG) Administrators Guide The Administrator will be prompted to reboot the switch whenever enabling or disabling AG The switchDisable command must be run to disable the switch before ag --modedisable command is issued