![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1572763.1 : T10000A/B - SNO FSC 2B30
T10K-A tape drive received SNO FSC 2B30 In this Document
Created from <SR 3-7597210064> Applies to:Sun StorageTek T10000A Tape Drive - Version All Versions to All Versions [Release All Releases]Sun StorageTek T10000B Tape Drive - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. The drive is at 1.48.105 Symptoms2B30 SNO FSC2B30 CauseMicrocode issue. Drive needs a special build of code. Drive SNO FSC is 2B30
SolutionT10000A/B - this error can occur on 1.48.105 (T10000A) and 1.48.205 (T10000B) code versions. One source of this error has been addressed in special build RF48.x05 code. A second cause for 2B30 errors is in RS48.x05 code. Note that the RS48.x05 code also contains the changes in RF48.x05 code. Please involve L2. See CR 7119976,7117426, and 7169124. Upgrade Firmware in T10K-A/B tape drives to special build RF.48.x05 FW for 2B30 SNO. Open a collab with Tape Product Expert to acquire this firmware. This fix will be added in future release firmware. TBD This issue is resolved in drive firmware. Open up a SR to request firmware upgrade. Attachments This solution has no attachment |
||||||||||||||||
|