Solution Type  Problem Resolution Sure

Solution  1570851.1 :   Ops Center Tool sent alert - critical alert on faulty component sensor number = 0x00. A generic system component error due to C: boot completed.  


Related Items
  • Sun Blade X6250 Server Module
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Blades>SN-x64: BLADE
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7545673901>

Applies to:

Sun Blade X6250 Server Module - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Critical alert on faulty component sensor number = 0x00. A generic system component error due to C: boot completed.

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems

Cause

The alert message received in Oracle's "Ops Center Tool" is referencing an O/S (Operating System) boot. This server has the Microsoft Windows O/S installed and since the O/S has gracefully rebooted, SEL (System Event Log) has reported the event "O/S Boot | C: boot completed".

 

4bcc | 07/16/2013 | 06:12:02 | OS Stop/Shutdown | OS graceful shutdown | Asserted
4bcd | 07/16/2013 | 06:12:02 | OEM record dd | 000137 | 00ff00008000
4bce | 07/16/2013 | 06:22:35 | System Boot Initiated | Initiated by warm reset | Asserted
4bcf | 07/16/2013 | 06:22:37 | System Firmware Progress | Primary CPU initialization | Asserted
4bd0 | 07/16/2013 | 06:22:37 | System Firmware Progress | Secondary CPU Initialization | Asserted
4bd1 | 07/16/2013 | 06:23:01 | System Firmware Progress | Video initialization | Asserted
4bd2 | 07/16/2013 | 06:23:11 | System Firmware Progress | Memory initialization | Asserted
4bd3 | 07/16/2013 | 06:23:11 | System Firmware Progress | Option ROM initialization | Asserted
4bd4 | 07/16/2013 | 06:24:06 | System Firmware Progress | System boot initiated | Asserted
4bd5 | 07/16/2013 | 06:25:02 | OS Boot | C: boot completed | Asserted
4bd6 | 07/16/2013 | 06:25:02 | OEM record dc | 000137 | 002ee7e45100

 

Solution

No fault with server hardware/software. This message is normal on a graceful reboot.
 