Asset ID: |
1-72-1569678.1 |
Update Date: | 2013-07-24 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1569678.1
:
OKM 2.5.2: Replication Lag Size Stuck Around 480k Size After Activating 2.5.2 OKM Version
Related Categories |
- PLA-Support>Sun Systems>TAPE>Backup Software-Filesystems>SN-TP: Encryption
|
In this Document
Created from <SR 3-7540243401>
Applies to:
Oracle Key Manager - Version 2.3 to 2.5.2 [Release 2.0]
Information in this document applies to any platform.
Symptoms
Customer upgrading his KMA's from 2.3.1 to 2.5.2 customer noticed "not responding" on the service network and lag size seems to be stuck at 480.
Changes
Recently upgraded OKM software from 2.3.1 to 2.5.2
Cause
Upgrade of the OKM software.
Solution
The status of "Not Responding" for the service network is normal if all the KMA's are not on the same subnet.
Noticed on two KMA's that were activated on 2.5.2, the lag size appears to be stuck at 480, this is also normal until all the KMA's have been activated and the replication levels are the same, level 14 for OKM 2.5.2.
References