Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1569568.1
Update Date:2018-03-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1569568.1 :   Sun Ultra 24 Workstation, CPU Fan Error Might Occur After Power On.  


Related Items
  • Sun Ultra 24 Workstation
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Workstations>SN-x64: WORKSTATION
  •  


Sun Ultra 24 Workstation,  CPU Fan Error Might Occur After Power On.

In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-7485946931>

Applies to:

Sun Ultra 24 Workstation - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Sun Ultra 24 is reporting "Chassis Fan Failed" on power on.

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems

Changes

 

Cause

 This is due to the Intel ME BIOS default settings for the CPU fan.

Solution

To prevent or resolve this issue, use the following procedure to access the Management Engine (ME) BIOS Setup utility and change the power policies.

This information will be added to a revision of the Sun Fire Ultra 24 Service Manual.  

To Access the ME BIOS Setup Utility and Set Power Policies go to URL:

   http://docs.oracle.com/cd/E19127-01/ultra24.ws/820-2478-17/index.html#0_25958

In case system is already affected by CPU fan error issue please got to listed URL below and perform Intel Management Engine Firmware Recovery Procedure:

   http://docs.oracle.com/cd/E19127-01/ultra24.ws/820-2478-17/index.html#0_45430

 