Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1568547.1
Update Date:2017-06-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  1568547.1 :   Blade ILOM cli Console Not Responding  


Related Items
  • Sun Blade X6250 Server Module
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Blades>SN-x64: BLADE
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7437544701>

Applies to:

Sun Blade X6250 Server Module - Version All Versions to Not Applicable [Release All Releases to N/A]
Information in this document applies to any platform.

Symptoms

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems

The server iLOM CLI (Command Line Interface) console may hang or not respond:

> cd cli /CH/BL0/SP/cli
 -> ls
 /CH/BL0/SP/cli
  Targets:

  Properties:
type = Blade CLI
user = root

  Commands:
cd
set
show
start
stop

-> start Are you sure you want to start /CH/BL0/SP/cli (y/n)? Y

 

Cause

Blade 0 (SP) Service Processor has potentially hung in this example.
 
It therefore has no response to the command to start BL0 session from the CMM.

And you are not able to login to blade ILOM directly through SSH & GUI.
 

Solution

Reset the BL0 blade ILOM from CMM by running below command:

-> reset /CH/BL0/SP

Blade operations will continue as normal.

Whilst the blade is out of production, consider updating SP firmware to the latest available to avoid potential future issues:

http://www.oracle.com/technetwork/systems/patches/firmware/release-history-jsp-138416.html