Solution Type Problem Resolution Sure Solution 1568485.1 : Cannot Reset Pendingipgateway Value On T6300 SP
In this Document
Created from <SR 3-7260064511> Applies to:Sun Blade T6300 Server Module - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsTroubleshooting steps on T6300 when changes to pendingipgateway value fails to commit Cannot reset or change pendingipgateway value on T6300 SP when executing the set commitpending=true Commmand Cause- The Blade is not powered on -Possible Faulty Dongle Cable -Dongle cable is not connected to the T6300 Blade - FW (firmware) needs to be upgrade and or Reflashed - faulty/failed Battery on the SP, faulty MB, and or Faulty SP. *see REFERENCES below* SolutionSteps to follow: If network settings still not correct, reset the CMM in order to recheck. If issue persists, please open a technical service request for further analysis by a SPARC Hardware Technical Service Engineer. References<NOTE:1452873.1> - How to Recognize and Diagnose a Sun Fire T2000/Sun Blade T6300/T6320/T6340 Service Processor Battery FailureAttachments This solution has no attachment |
||||||||||||||||||
|