Solution  1568485.1 :   Cannot Reset Pendingipgateway Value On T6300 SP  


Related Items
  • Sun Blade T6300 Server Module
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Usx/Blade/Netra>SN-SPARC: SB60xx
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-7260064511>

Applies to:

Sun Blade T6300 Server Module - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Troubleshooting steps on T6300 when changes to pendingipgateway value fails to commit

Cannot reset or change pendingipgateway value on T6300 SP when executing the set commitpending=true Commmand

This document will provide troubleshooting steps for when the following scenario is encountered:

- User is not able to gain access to the blade through the dongle
- The SP does not respond when the blade is inserted
- The blade is not accessible through the BUI as the T6300 does not support BUI accessibility
- The blade is accessible through the CMM.
- The blade will not take (save) any of the network settings using the setpending commands.

Cause

- The Blade is not powered on

-Possible Faulty Dongle Cable

-Dongle cable is not connected to the T6300 Blade

- FW (firmware) needs to be upgrade and or Reflashed

- faulty/failed Battery on the SP, faulty MB, and or Faulty SP. *see REFERENCES below*

Solution

Steps to follow:

1.Need to access/connect a DONGLE CABLE to The T6300 Blade and the Blade must be POWERED ON

2. reflash t6300 with latest fw - *do not save config* <--- when it asks to preserve answer NO (when doing the FW )

3. connect directly to t6300 via serial dongle,  *login as admin* and reconfigure network settings using:

setupsc
shownetwork
*How  To Use the setupsc Command:*
http://docs.oracle.com/cd/E19076-01/t1k.srvr/819-7991-10/command_shell.html#50524207_25999

4. connect to CMM

show /CH/BL#/SP/network

If network settings still not correct, reset the CMM in order to recheck. If issue persists, please open a technical service request for further analysis by a SPARC Hardware Technical Service Engineer.