Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1567458.1
Update Date:2017-09-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  1567458.1 :   T10000C - Perceived Problem With IPLing, Status LED Staying On  


Related Items
  • StorageTek T10000C Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

StorageTek T10000C Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

 The status LED stays flashing for a long time.

Cause

If you get a new drive and it stays in a mode where the status LED stays flashing for a long time this is normal. The drive has temperature sensors and will not complete the IPL process until the drive reaches a certain temperature. The drive may take 6 minutes or more for this to occur.

Solution

 Give the drive up to 10 minutes to complete the IPL process.