![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1567419.1 : VTSS/T10000C - Cannot Initialize Blank Tapes
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:StorageTek T10000C Tape Drive - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. SymptomsCannot initialize blank tapes using VTCS. VSM logs may show FSC 3627 sense data and assert message at the same time period.
CauseAssert is occurring in the VTSS hardware. This causes the re-initialize process to end. The drive you will see RSCN and PLOGI issued to it on the FICON interface after a Perform Subsystem Function (PSF) or Read Subsystem Data (RSD) command. SolutionIf this is on a CISCO FICON have the customer open a problem with their switch maintainer. Cisco has a firmware change in version v5.2(8a) to address this issue. they may want to reference Cisco problem number 626540351. Attachments This solution has no attachment |
||||||||||||||||
|