Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1565376.1
Update Date:2013-08-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  1565376.1 :   Brocade - What do "QOS Is Disabled" messages mean ?  


Related Items
  • Brocade 48000 Director
  •  
  • Brocade 24000 Director
  •  
  • Brocade 12000 Fabric Switch
  •  
  • Brocade 8000 FCoE Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7297334057>

Applies to:

Brocade 24000 Director - Version All Versions and later
Brocade 48000 Director - Version All Versions and later
Brocade 12000 Fabric Switch - Version All Versions and later
Brocade 8000 FCoE Switch - Version All Versions and later
Information in this document applies to any platform.

Symptoms

This is a Brocade 48000 switch with FOS 6.4.2a and they have configured some ports for FCIP (IP over FC).

With no apparent reason, starting on 26 May, we can see every day informational messages like this on the VE ports:

2013/05/26-11:57:33, [PORT-1010], 144813, SLOT 6 | FID 128, INFO, switch01, Port (ID: 200) QOS is disabled
2013/05/26-11:57:33, [PORT-1010], 144814, SLOT 6 | FID 128, INFO, switch01, Port (ID: 192) QOS is disabled
2013/05/26-11:57:33, [PORT-1010], 144815, SLOT 6 | FID 128, INFO, switch01, Port (ID: 200) QOS is disabled
2013/05/26-11:57:34, [PORT-1010], 144816, SLOT 6 | FID 128, INFO, switch01, Port (ID: 192) QOS is disabled
2013/05/26-11:57:39, [PORT-1010], 144818, SLOT 6 | FID 128, INFO, switch01, Port (ID: 136) QOS is disabled
2013/05/26-11:57:39, [PORT-1010], 144819, SLOT 6 | FID 128, INFO, switch01, Port (ID: 128) QOS is disabled
2013/05/26-11:57:39, [PORT-1010], 144821, SLOT 6 | FID 128, INFO, switch01, Port (ID: 136) QOS is disabled

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk/Tape Storage Area Networks

Cause

From "Fabric OS Message Reference 53-1001767-01" page 475 :

-----------------------------
PORT-1010
Message
, [PORT-1010], ,, WARNING, , Port (ID:) QOS is disabled.

Probable Cause
The Port QOS is disabled because the port currently has Best Effort Setting that requires QOS to be
disabled on a 4G or 8G long distance platform.

Recommended Action
This is normal; no action required.

Severity WARNING
-----------------------------

 

On the supportsave of Brocade 48000 switch switch01,
I can see you are using four Gigabit Ethernet ports as extender ports (VE)
to connect to the other switches of the fabric via FCIP

VE_Port: Virtual E_Port is used to connect two FCFs together and is the FCoE equivalent of a Fibre Channel E_Port.


fabricshow :
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
-------------------------------------------------------------------------
1: fffc01 50:00:51:e3:88:6e:ef:3b 0.0.0.0 0.0.0.0 "switch02"
5: fffc05 10:00:00:05:1e:36:48:80 10.0.0.1 0.0.0.0 >"switch01"
160: fffca0 50:00:51:e3:63:f2:ae:32 0.0.0.0 0.0.0.0 "switch03"

The Fabric has 3 switches

Number of domains: 3

1, 5, 160

islshow :
1:128->128 50:00:51:e3:63:f2:ae:32 160 switch03 sp:-------- bw: 0.985G
2:136->136 50:00:51:e3:63:f2:ae:32 160 switch03 sp:-------- bw: 0.985G
3:192->192 50:00:51:e3:63:f2:ae:32 160 switch03 sp:-------- bw: 0.985G
4:200->200 50:00:51:e3:63:f2:ae:32 160 switch03 sp:-------- bw: 0.985G


switchshow:
switchshow :
switchName: switch01
switchType: 42.2
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 5
switchId: fffc05
switchWwn: 10:00:00:05:1e:36:48:80
zoning: ON (DHS_DR)
switchBeacon: OFF
FC Router: OFF
FC Router BB Fabric ID: 1
Address Mode: 0

Index Slot Port Address Media Speed State Proto
===================================================

128 1 16 058000 -- -- Online VE VE-Port 50:00:51:e3:63:f2:ae:32 "switch03"
136 1 24 058800 -- -- Online VE VE-Port 50:00:51:e3:63:f2:ae:32 "switch03" (downstream)
1 ge0 id 1G Online FCIP
1 ge1 id 1G Online FCIP

192 7 16 05c000 -- -- Online VE VE-Port 50:00:51:e3:63:f2:ae:32 "switch03"
200 7 24 05c800 -- -- Online VE VE-Port 50:00:51:e3:63:f2:ae:32 "switch03"
7 ge0 id 1G Online FCIP
7 ge1 id 1G Online FCIP


Starting on 26 May, we can see every day informational messages like this on the VE ports:

2013/05/26-11:57:33, [PORT-1010], 144813, SLOT 6 | FID 128, INFO, switch01, Port (ID: 200) QOS is disabled
2013/05/26-11:57:33, [PORT-1010], 144814, SLOT 6 | FID 128, INFO, switch01, Port (ID: 192) QOS is disabled
2013/05/26-11:57:33, [PORT-1010], 144815, SLOT 6 | FID 128, INFO, switch01, Port (ID: 200) QOS is disabled
2013/05/26-11:57:34, [PORT-1010], 144816, SLOT 6 | FID 128, INFO, switch01, Port (ID: 192) QOS is disabled
2013/05/26-11:57:39, [PORT-1010], 144818, SLOT 6 | FID 128, INFO, switch01, Port (ID: 136) QOS is disabled
2013/05/26-11:57:39, [PORT-1010], 144819, SLOT 6 | FID 128, INFO, switch01, Port (ID: 128) QOS is disabled
2013/05/26-11:57:39, [PORT-1010], 144821, SLOT 6 | FID 128, INFO, switch01, Port (ID: 136) QOS is disabled


Currently the QOS is disabled on all ports of the switch, see:

portcfgshow :

Ports of Slot 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
-----------------+---+---+---+---+-----+---+---+---+-----+---+---+---+-----+---+---+---
Speed 2G 2G AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Fill Word 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
AL_PA Offset 13 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent Disable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
LOS TOV enable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
NPIV PP Limit 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126
QOS E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
EX Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Mirror Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
FC Fastwrite .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Fport Buffers .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Port Auto Disable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Fault Delay 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Ports of Slot 1 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
-----------------+---+---+---+---+-----+---+---+---+-----+---+---+---+-----+---+---+---
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Fill Word 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
AL_PA Offset 13 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent Disable .. ON ON ON ON ON ON ON .. ON ON ON ON ON ON ON
LOS TOV enable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
NPIV PP Limit 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126
QOS E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
EX Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
FC Fastwrite .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Fport Buffers .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Port Auto Disable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Fault Delay 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
where AE:QoSAutoEnable, AN:AutoNegotiate, ..:OFF, NA:NotApplicable, ??:INVALID,



Ports of Slot 7 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
-----------------+---+---+---+---+-----+---+---+---+-----+---+---+---+-----+---+---+---
Speed 2G 2G AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Fill Word 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
AL_PA Offset 13 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent Disable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
LOS TOV enable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
NPIV PP Limit 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126
QOS E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
EX Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Mirror Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
FC Fastwrite .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Fport Buffers .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Port Auto Disable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Fault Delay 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Ports of Slot 7 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
-----------------+---+---+---+---+-----+---+---+---+-----+---+---+---+-----+---+---+---
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Fill Word 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
AL_PA Offset 13 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent Disable .. ON ON ON ON ON ON ON .. ON ON ON ON ON ON ON
LOS TOV enable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
NPIV PP Limit 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126
QOS E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
EX Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
FC Fastwrite .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Fport Buffers .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Port Auto Disable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Fault Delay 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
where AE:QoSAutoEnable, AN:AutoNegotiate, ..:OFF, NA:NotApplicable, ??:INVALID,
 

Solution

If QOS is disabled on the configuration,  the QOS messages can be ignored.

From "Fabric OS Message Reference 53-1001767-01" page 475 :

-----------------------------
PORT-1010
Message
, [PORT-1010], ,, WARNING, , Port (ID:) QOS is disabled.

Probable Cause
The Port QOS is disabled because the port currently has Best Effort Setting that requires QOS to be
disabled on a 4G or 8G long distance platform.

Recommended Action
This is normal; no action required.

Severity WARNING
-----------------------------

If QOS is not disabled, collect a supportsave of the switch and contact with Oracle support.

For more information see this other discussion on Brocade community:;

Many QOS Warning Messages Are Reported
http://community.brocade.com/thread/4304?start=0&tstart=0

"QoS disable" message
http://community.brocade.com/message/10000#10000


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback