![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1564533.1 : VLE UUI Port Configuration Limitation
In this Document
Applies to:Sun Virtual Library Extension (VLE) - Version 1.0 to 1.3 [Release 1.0]Information in this document applies to any platform. SymptomsBoth UUI ports fail when a single UUI port fails or one of the UUI port cables is disconnected. CauseIt is common practice to configure VLE UUI ports with both a primary and alternate UUI port. However, if both UUI ports are within the same subnet then the failure of either port or cable removal from either UUI port can result in the remaining UUI port becoming inoperative. This is reproducible in our labs and there is no fix planned to address this behavior. Solaris documentation recommends against this configuration unless the ports are configured for IPMP. However, VLE engineering has not tested IPMP on the VLE UUI ports and therefore this option is not recommended. SolutionThere are two options available for addressing this issue:
Attachments This solution has no attachment |
||||||||||||||||
|