![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1563950.1 : Fault occurred because QPIRC initialization was unable to complete within 10 seconds.
In this Document
Created from <SR 3-7425790111> Applies to:Sun Server X3-2 - Version Not Applicable and laterInformation in this document applies to any platform. SymptomsTo discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems
Initialization of the QPIRC was not successfully completed. CauseFault occurred because QPIRC initialization was unable to complete within 10 seconds. Solution- Clear the fma fault. - Reset the ILOM SP Operating System. - Reset the server. - Allow the platform to boot normally. References<NOTE:1174515.1> - SPX86-8002-4Q - Initialization of the QPIRC was not successfully completed.Attachments This solution has no attachment |
||||||||||||||||||
|