Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1560833.1
Update Date:2013-07-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  1560833.1 :   Pillar Axiom: The Fibre Channel Port status of FC V2 Bricks may not be correctly reported  


Related Items
  • Pillar Axiom 500 Storage System
  •  
  • Pillar Axiom 600 Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Axiom>SN-DK: Ax600
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-7329396151>

Applies to:

Pillar Axiom 600 Storage System - Version All Versions to All Versions [Release All Releases]
Pillar Axiom 500 Storage System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

In Pillar Axiom version 5.4, the Fibre Channel Ports are not reported for Fibre Channel V2 Bricks. 
The<FibreChannelPort> elements are missing for the RaidControllers beginning with Axiom version 5.4. 

Fibre Channel Bricks are affected.  SATA Bricks appear to have the required information.  It existed for both SATA and FC Bricks in Axiom version 5.3.

Below is what it looks like in Axiom Version 5.3, chsh.xml file:

 

@ <RaidController>
@               <HardwareComponentStatus>NORMAL</HardwareComponentStatus>
@               <TemperatureStatus>NORMAL</TemperatureStatus>
@               <Model>1450-00076-31</Model>
@               <SerialNumber>GE0650021471071633</SerialNumber>
@               <FirmwareVersion>2050-00038-012111-012111</FirmwareVersion>
@               <Number>0</Number>
@               <FibreChannelPort>
@                 <PortStatus>CONNECTED</PortStatus>
@                 <ConnectorId>FC0</ConnectorId>
@                 <ConnectionType>COPPER</ConnectionType>
@                 <MaximumSpeed>0</MaximumSpeed>
@                 <Speed>2000000000</Speed>
@                 <Topology>POINT_TO_POINT</Topology>
@                 <PortSfpStatus>INVALID</PortSfpStatus>
@                 <SfpVendorName/>
@                 <SfpPartNumber/>
@                 <SfpRevision/>
@               </FibreChannelPort>
@               <FibreChannelPort>@                    . . .

 

From Axiom 5.4 chsh.xml file:

@  <RaidController>
@               <HardwareComponentStatus>NORMAL</HardwareComponentStatus>
@               <TemperatureStatus>NORMAL</TemperatureStatus>
@               <Model>1450-00256-32</Model>
@               <SerialNumber>USE20000266LA0C8</SerialNumber>
@               <FirmwareVersion>2050-00045-022314-022314</FirmwareVersion>
@               <Number>1</Number>
@  </RaidController>
@  <RaidController>

@        . . .

On the Axiom GUI of R5.4.1 Brick details are displayed with no I/O Ports.

 FC_V2 brick with no I/O Ports

 

Cause

This issue was injected in Patch 05.04.01.   The defect below was filed with Engineering

Bug:16594665 - 2ND GEN FC BRICK PORT STATUS REPORTING NOT WORKING

Solution

 This defect has been fixed in R5.4.5.  Release notes and implementation details are in Pillar Axiom: Ax600 & Ax500 Patch 05.04.05 for SAN [ID 1568094.1]

References

<NOTE:1568094.1> - Pillar Axiom: Ax600 & Ax500 Patch 05.04.05 for SAN
<BUG:16594665> - 2ND GEN FC BRICK PORT STATUS REPORTING NOT WORKING