![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1560814.1 : Sun Storage 7000 Unified Storage System: Solaris Fault Manager received an event FMD-8000-0W (after DIMM failure)
In this Document
Applies to:Sun Storage 7410 Unified Storage System - Version All Versions and laterSun ZFS Storage 7120 - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later Sun ZFS Storage 7320 - Version All Versions and later Sun Storage 7310 Unified Storage System - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsTo discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage ZFS Storage Appliance
The customer received an ASR alert that showed the fault manager (FMD) had an event that it was unable to process: --------------- -------------------------------------------------------------- -------------- ---------
ChangesNone CauseIf there has been a DIMM failure with an event SENSOR-8000-AM - then a secondary event of FMD-8000-OW can be generated several days later - if there has been a delay in replacing the faulty component. For example - this is the related Alert for the appliance NAS-1 that had a DIMM failure: chassis-000 NAS-1 faulted Oracle Sun ZFS Storage 7420
But then also saw this alert opened before the faulty component (a DIMM) was replaced. --------------- ------------------------------------------------------------- -------------- ---------
Then this event code FMD-8000-0W was received. "Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed."
SolutionThe event FMD-8000-0W will not cause any impact on the ZFS storage. To confirm the cause: Open the appliance BUI and access the Maintenance > Problems page to confirm if a related DIMM event was generated. Also the Maintenance > hardware will show an amber icon against the head unit - and the failed component. If yes - an ASR will have been sent to Oracle to open a Service Request to have the component replaced. Confirm the MOS SR is open and that the supportbundle has been provided.
To provide a support bundle follow the instructions in this document: 1019887.1 - Sun Storage 7000 Unified Storage System: How to collect a supportbundle using the BUI or CLI
Once the DIMM has been replaced, both FMD events SENSOR-8000-AM and FMD-8000-OW can be 'markrepaired' on the Maintenance Problems page. References<NOTE:1324432.1> - Sun Storage 7000 Unified Storage System: 7xx0 Memory Troubleshooting<NOTE:1278341.1> - Sun ZFS Storage Appliance: How to determine the DIMM CRU used in a 7210 or 7320 NAS. <NOTE:1019887.1> - Sun Storage 7000 Unified Storage System: How to collect a supportbundle using the BUI or CLI Attachments This solution has no attachment |
||||||||||||||||||||
|