Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1560480.1
Update Date:2015-09-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  1560480.1 :   VTCS returns the UUIREQ ERROR CC=30 RC=4 to the main frame console  


Related Items
  • Sun Virtual Library Extension (VLE)
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7304920411>

Applies to:

Sun Virtual Library Extension (VLE) - Version 1.1 to 1.2 [Release 1.0]
Information in this document applies to any platform.
The customer receives UUIREQ ERROR CC=30 RC=4 while trying to mount an already defined VMVC . Subsequent Audits of the VMVC indicate the VMVC can not be found

Symptoms

  STC00728 00000291  ?SLS6894I M V0XX,MXXXX,SL,,VTSSXX,SWSRDRC,HSMML2A
 STC00728 00000090  ?SLS6684I RTD VLERTDXX ON VTSS VTSS01 RETURNED UUIREQ ERROR CC=30 RC=4
 STC00728 00000090  ?SLS6693I RTD VLERTDXX FAILED, DRIVE WILL BE RETRIED LATER
 STC00728 00000090  ?SLS6628E RTD VLERTDXX ON VTSS VTSSXX FAILED TO MOUNT MVC MXXXXX
 STC00728 00000090  ?SLS6684I RTD VLERTDXX ON VTSS VTSSXX RETURNED UUIREQ ERROR CC=30 RC=4
 STC00728 00000090  ?SLS5079E MOUNT OF LXXXXX ON 04EA - FAILED (12) - MVC:MXXXXX  REMOTE
                              COMMAND ERROR CC=30 RC=4
 STC00728 00000090  ?SLS6628E RTD VLERTDXX ON VTSS VTSSXX FAILED TO MOUNT MVC MXXXXX

 

Cause

 The VLE microcode below 1.3.12 has a problem where the VMVC is removed form the coherence cache table. 

Solution

 Create an onsite task and have the cse verify in the VLE GUI the VMVC is not there.

If the VMVC does not display in the VLE gui  stop the vle services on all nodes and restart them.

This will cause the coherence cache to refresh and the VMVC will be available.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback