Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1560166.1
Update Date:2013-06-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  1560166.1 :   VLE - Receiving Critical Notifications for Manual Data Collection  


Related Items
  • Sun Virtual Library Extension (VLE)
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VLE
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7281761420>

Applies to:

Sun Virtual Library Extension (VLE) - Version 1.0 to 1.3 [Release 1.0]
Information in this document applies to any platform.

Symptoms

Receiving the following e-mail alerts and alarms in CAM.

Alarm Id         : alarm1
Severity         : Critical
Type             : vle.LogEvent
Topic            : VLE1A1_vle
Event Code       : -
Date             : 2013-05-24 00:00:31
Device           : VLE1A1_vle[AK00031693]
Description      : May 24 00:00:01 VLE1A1_vle VLE1A1_vle: [ID 2000] CRITICAL:
                   Manual Data Collection.

Cause

 The e-mail alerts and alarms for the CRITICAL: Manual Data Collection is working as designed.  E-mail alerts and CAM alarms will be generated for each automated support bundle generated or run, typically at midnight of each day.

Solution

When a support bundle is generated or manually run, an alert will be generated and the description will indicate "CRITICAL".  This is working as designed and will not be changed by engineering.  In order to not receive the e-mail alerts, remove the e-mail address in CAM to which alerts are sent.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.