Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1559901.1
Update Date:2017-10-25
Keywords:

Solution Type  Problem Resolution Sure

Solution  1559901.1 :   Sun Storage C4 Tape Library: Servo Initialization Failure - Error: C2AE2410  


Related Items
  • Sun Storage C4 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-7338431701>

Applies to:

Sun Storage C4 Tape Library - Version Not Applicable and later
Information in this document applies to any platform.

C4- EOL Product

Symptoms

Getting following messages "Servo init failure".

Troubleshooting steps taken: Removed the top cover and checked robot movement, it was not moving.

FA log from library reporting:

        0221: ThreadId: Servo, Severity: Critical, Class: Servo init failure.

               EventId: Servo Initialization Failure
               Error: C2AE2410, Context: 0404/00000002, 2013-Jun-06, 08:41:16.206, 
      
 



Cause

Robot assembly failed.

Robot's umbilical cable was damaged.

Solution

If "Servo Initialization Failure" errors repeats frequently, then CSE is required to replace Robot and check Robotic umbilical cable.

See two internal references below:

How to Remove / Replace Hand Assembly (Picker ASM) in C4 Library:ATR:1013598.1:2

Solution Next higher Assembly if cable should be damaged - f380-1503 [F] C4 0 Drive Chassis, RoHS:YL f380-1558 [F], Hand Umbilical Cable

[Article ID 1013598.1]

Field reliability issues can be induced by failing to follow the Hand FRU replacement procedures for the Sun StorageTek C4 Tape Library. [ID 1000959.1]

If "Servo Initialization Failure" errors does not repeat frequently, then library auto corrected itself and no action is required. But customer can provide FA log for further analysis.

C4 - How to Collect Failure Analysis / Dump File to Troubleshoot Tape Library [ID 1008240.1]

References

<NOTE:1013598.1> - How to Remove / Replace Hand Assembly (Picker ASM) in C4 Library:ATR:1013598.1:2
<NOTE:1000959.1> - Field reliability issues can be induced by failing to follow the Hand FRU replacement procedures for the Sun StorageTek C4 Tape Library.
<NOTE:1018482.1> - C2/C4 - Failure Analysis Manual
<NOTE:1008240.1> - C4 - How to Collect Failure Analysis / Dump File to Troubleshoot Tape Library

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback