Created from <SR 3-6929441291> Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]Sun StorageTek T10000 Tape Drive - Version Not Applicable and later Sun StorageTek 9840 Tape Drive - Version Not Applicable and later Sun StorageTek 9940 Tape Drive - Version Not Applicable and later Information in this document applies to any platform. RTD = Real Tape Drive SymptomsConsole reporting IOS551I NO PATHS PHYSICALLY AVAILABLE
CauseRTD went offline. RTD dropped power. RTD dropped communication to library interface. RTD dropped communication to mainframe system. SolutionField Engineer is required to perform following: Re-seat the drive in the Bay/Tray and verify availability of drive to library, as to the HSC system. Check cable seating, plugs, controller connections. Attachments This solution has no attachment |
||||||||||||||||
|