Solution Type  Problem Resolution Sure

Solution  1558183.1 :   T10000/9840/9940 - IOS551I, No Pathes Physically Available  


Related Items
  • Sun StorageTek T10000 Tape Drive
  •  
  • Sun StorageTek 9840 Tape Drive
  •  
  • Sun StorageTek 9940 Tape Drive
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-6929441291>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek T10000 Tape Drive - Version Not Applicable and later
Sun StorageTek 9840 Tape Drive - Version Not Applicable and later
Sun StorageTek 9940 Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.
RTD = Real Tape Drive

Symptoms

Console reporting IOS551I NO PATHS PHYSICALLY AVAILABLE 

 

Cause

RTD went offline.

RTD dropped power.

RTD dropped communication to library interface.

RTD dropped communication to mainframe system.


Solution

Field Engineer is required to perform following:

Re-seat the drive in the Bay/Tray and verify availability of drive to library, as to the HSC system.

Check cable seating, plugs, controller connections.


Attachments