Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1555879.1
Update Date:2018-02-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  1555879.1 :   VSM/9840D - SLS6684I RTD XXXX ON VTSS YYYYYY RETURNED ECAM ERROR CC=5 RC=108  


Related Items
  • Sun StorageTek VSM5 System
  •  
  • Sun StorageTek 9840D Tape Drive
  •  
  • Sun StorageTek 9840C Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7254673221>

Applies to:

Sun StorageTek VSM5 System - Version All Versions and later
Sun StorageTek 9840D Tape Drive - Version Not Applicable and later
Sun StorageTek 9840C Tape Drive
Information in this document applies to any platform.

Symptoms

R/W errors  FSC3FC8

ECAM ERROR CC=5 RC=108
SLS6625E RTD XXXX REPORTED LOCATE BLK FAILURE: 00C0204440002E2001003FC837E8377835E5000000000000CE0E462086900000

 

Cause

Did not find the append point within the 10ms window, after gap was received during a Read Transfer operation.
 

Solution

What needs to be checked is System/VSM/ library log, to see if the MVC or drive failed on more than one drive or more than one MVC.

In the first instance the MVC failed on more than one drive, then drain/eject the MVC.  Otherwise, replace the drive.

If there was only one occurrence/event, monitor for further events, before taking any action.

This error code was seen on a 9840D drive.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback