ECAM Errors On CLINK RVAVSM1/1B
Related Items |
- Sun StorageTek VSM5 System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VLE
- _Old GCS Categories>Support>CriticalPatchUpdates>Sun Products
|
In this Document
Created from <SR 3-7182374241>
Applies to:
Sun StorageTek VSM5 System - Version All Versions and later
Oracle Solaris on x86-64 (64-bit)
Symptoms
:SLS6758I CLINK STKVSM1/1B IPIF 0I:3 failed to replicate VTV A12345
:SLS6751I CLINK STKVSM1/1B IPIF 0I:3 Returned ECAM error CC=5 RC=109
:SLS6667I Request purged:Replicate VTV VTV:A12345 ECAM error CC=5 RC=109
Changes
Switch modification (code upgrade) on the customer network
Cause
After a switch modification (code upgrade) VSM IP C-Link communications failed.
Problem could also show up as a problem on VSM5 to VLE vRTD communication failure.
Other possible causes that can result in this issue:
1. Faulty switch.
2. Modification (code upgrade) to the switch.
3. After a switch modification/replacement, improper reset of the IFF card.
4. Bad IFF card
If the error is the result of (1) or (2). then there is a possibility that the IFF card might not have gotten reset properly after the switch work was done.
Solution
- Have the switch vendor check the switch - if a recent code upgrade was done it may be necessary to downgrade the code.
- Check for the physical cable and switch ports
- If you see “inbound connection lost” errors messages logging consistently, check the IFF cards.
- Validate IFF IP Path
- First try the less disruptive and quicker step of doing a GFR No Replace of the associated IFF card in the VLE machine that is reporting the dropped connections. The GFR No Replace might correct the issue with dropped connections.
- If GFR No Replace does not resolve the issue, replace the IFF cards.