Asset ID: |
1-72-1554796.1 |
Update Date: | 2017-05-19 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1554796.1
:
SL8500 - Standby LED is Lit on HBT card, Entire Library Out of Production
Related Items |
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Created from <SR 3-7230903651>
Applies to:
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Standby LED is Lit, Amber, on HBT card, entire Library is out of Production.
Cause
Ethernet Switch is dead.
Solution
3Com Switch, 15 ports, the internal PSU (Power Supply Unit) is not functional and needs to be replaced. Replaced the failed 3com with a customer´s Cisco with no problems.
SL8500 - Loss of PDU-1 Will Cause Library to Become Inoperative (ID 1381938.1)
The old versions of SL8500 came with a 3com 16 port Switch (3C16470) with no redundant internal PSU, the new ones have 32 ports with redundant internal PSU (32-Port Ethernet Switch Assembly, PUE).
This is a brief resume of steps/checks executed on site by FE.
- Reboot via OP (SLC) OK.
- Power off/on LSM 2 OK
- System Power Off/on. OK
- Logging on OP (SLC) failed => cannot connect to server.
- Logging via SLC on HBC ok.
- Extract snapshot log and error log ok.
- Logging via CLI and typing commands like:
SL8500> network print
Host Name: sl8500_01
Gateway: 10.185.xxx.x
2B IP Address: 10.185.xxx.xx
2B Subnet Mask: 255.255.xxx.xxx
2B MAC Address: 00:10:4F:07:D4:12
2A IP Address: 129.80.xxx.xx
2A Subnet Mask: 255.255.xxx.x
2A MAC Address: DA:BE:EF:00:13:17
COMPLETED
version print
requestId
requestId 401
Attributes
Component List
Component
Date
Flash Version FRS_8.05 (6.86.00)
Name build_version
Version FRS_8.05
Component
Date Wed Nov 28 22:19:52 2012
Flash Version 6.84.15
Name controller.cramfs
Version 6.84.15
Component
Date Thu Nov 8 17:52:20 2012
Flash Version 6.84.13
Name disk.hbc.pImage
Version 6.84.13
Component
Date Thu Feb 12 19:00:56 2009
Flash Version 4.91.03
Name jre.cramfs
Version 4.91.03
Component
Date Thu Nov 8 17:50:06 2012
Flash Version 4.75.15
Name kernel.pImage
Version 4.75.15
Component
Date Thu Nov 8 17:50:36 2012
Flash Version 6.66.06
Name libs.cramfs
Version 6.66.06
Component
Date Thu Nov 8 19:00:51 2012
Flash Version 6.84.15
Name snmp.tarball
Version 6.84.15
Component
Date Thu Jun 10 14:17:05 2010
Flash Version 1.15.00
Name u-boot.bin
Version 1.15.00
Object Device 1,0,0,0,0 - library
Done
Failure Count 0
Success Count 8
COMPLETED
SL8500>
SL8500> hbt status *
requestId
requestId 1401
Attributes Fault Led off
Healthy true
Present true
Reset Board off
Select enable
Object Card hbta
Attributes Fault Led off
Healthy false
Present false
Reset Board off
Select enable
Object Card hbtb
Done
Failure Count 0
Success Count 2
COMPLETED
- FE onsite to check and replace power supplies Address: 1,0,0,1,23 and 1,0,0,1,24.
These PS were switched between other LSMs. Checked OK
- Access Doors, Safety door, Emergency red button (robotics Stop). All checked OK.
Relays (noise "clank" ok) opening or closing switches over all devices OK on HBN.
- HBN Power on Led. Checked Green light OK.
- Replace HBT card, replaced OK => same behavior as the original one. Roll back of HBT (previous one) ok.
- Disconnect all handbots on all LSMs OK.
- Disconnect and remove partially all tape drives. OK
- Power off/on ECM and reboot. OK
- Switch on/off all LSM HBS modules. OK
Attachments