Solution Type  Problem Resolution Sure

Solution  1554746.1 :   Boot Error: Wrong Uboot CRC For Data=[*200a0000, Len=60000] In Pkg *20100000  


Related Items
  • Sun Server X3-2
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Server>SN-x86: Sun Server X3
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-7226979581>

Applies to:

Sun Server X3-2 - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

SP boot failure

Wrong uboot CRC for data=[*200a0000, len=60000] in pkg *20100000

Changes

 SP firmware update

Cause

ILOM SP firmware corruption.

ILOM SP O/S corruption after ILOM firmware upgrade and throws below error while SP boot:

Wrong uboot CRC for data=[*200a0000, len=60000] in pkg *20100000
 

Solution

Recover the SP Firmware Image Using the Preboot Menu.

http://docs.oracle.com/cd/E23161_01/html/E23099/gkxih.html

 For net flash use  .pkg   ILOM firmware update file in the patch.