Solution Type Problem Resolution Sure Solution 1554746.1 : Boot Error: Wrong Uboot CRC For Data=[*200a0000, Len=60000] In Pkg *20100000
In this Document
Created from <SR 3-7226979581> Applies to:Sun Server X3-2 - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. SymptomsSP boot failure Wrong uboot CRC for data=[*200a0000, len=60000] in pkg *20100000 ChangesSP firmware update CauseILOM SP firmware corruption. ILOM SP O/S corruption after ILOM firmware upgrade and throws below error while SP boot: Wrong uboot CRC for data=[*200a0000, len=60000] in pkg *20100000 SolutionRecover the SP Firmware Image Using the Preboot Menu. http://docs.oracle.com/cd/E23161_01/html/E23099/gkxih.html For net flash use .pkg ILOM firmware update file in the patch. Attachments This solution has no attachment |
||||||||||||||||||
|