Created from <SR 3-7218603237> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. SymptomsAfter the customer rebooted the library to complete the firmware upgrade, the library will not come back online. Robot is not operational! Current status is: Inoperative. 2013-05-14 07:47:30
0093 - ROBOT_HAND_CPU_COMM_FAILURE - Fault Code:9122
Result code 9122, RC9122, FSC9122 2013-05-14 07:46:32
0092 - ROBOT_HAND_CPU_COMM_FAILURE - Fault Code:9122
CauseDefective robotics module. SolutionAt this time, the robotic module should be replaced. Attachments This solution has no attachment |
||||||||||||||||||
|