Symptoms

After the customer rebooted the library to complete the firmware upgrade, the library will not come back online.

Robot is not operational! Current status is: Inoperative.
 

2013-05-14 07:47:30
0093 - ROBOT_HAND_CPU_COMM_FAILURE - Fault Code:9122

 

Result code 9122, RC9122, FSC9122

2013-05-14 07:46:32
0092 - ROBOT_HAND_CPU_COMM_FAILURE - Fault Code:9122

 

Cause

Defective robotics module.
 

Solution

At this time, the robotic module should be replaced.
<Document 1473774.1> SL150 - How to Remove/Replace the Robot CRU in a StorageTek SL150 Modular Tape Library

Make sure the firmware is upgraded before handing the SL150 back to the customer.
 