Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1554328.1
Update Date:2018-02-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  1554328.1 :   T10000 - 24: This Trap Is Sent When A New Dump Is Detected, FSC37F3  


Related Items
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-7227443715>

Applies to:

Sun StorageTek T10000B Tape Drive - Version Not Applicable and later
StorageTek T10000C Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

Dump FSC FFFA with event , FSC: 37F3

Uncorrectable ECC error detected during a read.
 

Cause

Uncorrectable ECC error detected during a read.
 
This is most likely a media problem.

FSC Encountered: 37F3   volser=xxxxx
(FSC Exact Match Found)
FSC: 37F3    |***             | ***            | ***            |
MIM Code:    NONE

FRU:        MEDIA          CONF: 100%

Field Text:
Uncorrectable ECC error detected during a read.
 

Solution

This problem could be a media or a drive issue.
The error posted seems to be related most likely to media problem;
In any case more data points needed, so the drive and media could be checked in the next days for new events.
If possible the media could be removed from library.

No more actions need for this alert.
 

References

<NOTE:1222086.1> - T10000 - Drive Wear Out Criteria - Tape Alert 24

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback