![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1554328.1 : T10000 - 24: This Trap Is Sent When A New Dump Is Detected, FSC37F3
In this Document
Created from <SR 3-7227443715> Applies to:Sun StorageTek T10000B Tape Drive - Version Not Applicable and laterStorageTek T10000C Tape Drive - Version Not Applicable and later Information in this document applies to any platform. SymptomsDump FSC FFFA with event , FSC: 37F3 Uncorrectable ECC error detected during a read. CauseUncorrectable ECC error detected during a read. FSC Encountered: 37F3 volser=xxxxx SolutionThis problem could be a media or a drive issue. No more actions need for this alert. References<NOTE:1222086.1> - T10000 - Drive Wear Out Criteria - Tape Alert 24Attachments This solution has no attachment |
||||||||||||||||||
|