![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1553503.1 : T10000A - Failing With FSC FE01
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000A Tape Drive - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. SymptomsDrive has wakeup error. FSCFE01, FE01 Changes
CauseFSC: FE01 |WAKEUP DIAG |FAILED |REGISTER VALUE | SolutionTry to reboot the drive one more time. If the wakeup error is still in place, replace drive. Note: Make sure the drive firmware is at current levels. Attachments This solution has no attachment |
||||||||||||||||||
|