Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1553503.1
Update Date:2018-02-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  1553503.1 :   T10000A - Failing With FSC FE01  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only
Created from <SR 3-7212528071>

Applies to:

Sun StorageTek T10000A Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Drive has wakeup error.

FSCFE01, FE01

Changes

 

Cause

FSC: FE01    |WAKEUP DIAG     |FAILED          |REGISTER VALUE  |
MIM Code:    INOPERABLE

FRU:        HARDWARE       CONF: 95%
FRU:        MICROCODE      CONF: 5%

Field Text:
The DC hardware compression wakeup diagnostic failed.

Solution

Try to reboot the drive one more time.  If the wakeup error is still in place, replace drive.

Note: Make sure the drive firmware is at current levels.


 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback