Solution Type  Problem Resolution Sure

Solution  1552692.1 :   SL3000: Tape Drive 0,0,12,8 Failed and is damaging tapes on write  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  


Specific for this customers issue.

In this Document
Symptoms
Cause
Solution


Created from <SR 3-7197154691>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Tapes are physically damaged from load and produce write errors

Cause

0,0,12,8 IBM LTO4 FC Damaging tapes multiple tapes.
 
Drive has damaged tapes and is producing errors on write after use and needs to be replaced
 

Solution

 Drive to be replaced with part number 7057446 IBM LTO4 FC and tested by engineer.

Tapes to send off for recovery if needed to third party for LTO media recovery