![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1551979.1 : SL8500 - Library is Down, No Power to Rails
In this Document
Created from <SR 3-7182888391> Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. Symptoms6 power supplies failed in the SL8500 tape library. Below is the SL8500 addresses for the power supplies. All are rail power supplies. 1,0,0,1,17 1,0,0,1,18 1,0,0,1,25 1,0,0,1,26 1,0,0,1,5 1,0,0,1,6. All 4 handbots were inoperative along with the CAP and elevator. AC power ok - false, DC power ok - false No power to the library rails. CauseIt appears that the left front library door was open/not closed all the way which caused the library to cut power to all rails. This could also be caused by someone pressing the ERS (Emergency Robotic Stop) button on the front of the library. SolutionClosed left front library door. Verify all devices, handbots, CAP, elevator, power supplies, etc. come back online via SL Console. Attachments This solution has no attachment |
||||||||||||||||
|