Solution Type  Problem Resolution Sure

Solution  1551601.1 :   T10000C - IFCC and SIM errors on drives behind a Cisco MDS-9513 Switch  


Related Items
  • StorageTek T10000C Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7166861311>

Applies to:

StorageTek T10000C Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

IFCC Interface Control Checks) and SIM errors trying to validate paths for RTDs (Real Tape Drives) behind the MDS-9513 switch.

Note: A SIM is an error description that will show up as part of an IOS000I message.  It indicates that an IO operation timed out.

Cause

 Trying to validate paths to remote RTDs.

Solution

 Have the customer contact whomever maintains their switches and mention code version v5.2.1c.

This has a fix for problems like this.

See SR 3-7166861311 for details.