Created from <SR 3-7166861311> Applies to:StorageTek T10000C Tape Drive - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. SymptomsIFCC Interface Control Checks) and SIM errors trying to validate paths for RTDs (Real Tape Drives) behind the MDS-9513 switch. Note: A SIM is an error description that will show up as part of an IOS000I message. It indicates that an IO operation timed out. CauseTrying to validate paths to remote RTDs. SolutionHave the customer contact whomever maintains their switches and mention code version v5.2.1c. This has a fix for problems like this. See SR 3-7166861311 for details. Attachments This solution has no attachment |
||||||||||||||||
|