![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1549711.1 : SL150 - LTO Drive Overtemp Error 9032
In this Document
Created from <SR 3-7138367351> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. 0032 - DRIVE_OVERTEMP_ERROR - Fault Code:9032 SymptomsDrive has failed and SL150 is now running in degraded mode
CauseDrive and or fan has failed.
Solution0032 - DRIVE_OVERTEMP_ERROR - Fault Code:9032 Check fan is not obstructed Replace drive assembly Ensure SL150 is updated to current firmware follow DOC ID 1474172.1 References<NOTE:1474172.1> - SL150 - How to Find Code Update Patches and Upgrade the StorageTek SL150 Modular Tape Library With Those PatchesAttachments This solution has no attachment |
||||||||||||||||||
|