Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1549711.1
Update Date:2017-05-19
Keywords:

Solution Type  Problem Resolution Sure

Solution  1549711.1 :   SL150 - LTO Drive Overtemp Error 9032  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-7138367351>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
0032 - DRIVE_OVERTEMP_ERROR - Fault Code:9032

Symptoms

Drive has failed and SL150 is now running in degraded mode

 

Cause

Drive and or fan has failed.
 

Solution

0032 - DRIVE_OVERTEMP_ERROR - Fault Code:9032

Check fan is not obstructed

Replace drive assembly

Ensure SL150 is updated to current firmware follow DOC ID 1474172.1

References

<NOTE:1474172.1> - SL150 - How to Find Code Update Patches and Upgrade the StorageTek SL150 Modular Tape Library With Those Patches

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback