Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1549484.1
Update Date:2017-06-07
Keywords:

Solution Type  Problem Resolution Sure

Solution  1549484.1 :   Tape - Issue With Library Connection via CLI Cable Directly to FSE Laptop  


Related Items
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek SL500 Modular Library System
  •  
  • Sun StorageTek L700e Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Connectivity Issues
Created from <SR 3-5790941331>

Applies to:

Sun StorageTek SL500 Modular Library System - Version All Versions and later
Sun StorageTek L700e Tape Library - Version Not Applicable and later
Sun StorageTek L180 Tape Library - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

Communication issues between FSE laptop and CLI port of the Library´s Controller Card.

There is no access to the library.

Tried 3 standard serial cables, one from Oracle, one from Cisco and one from Netapp but still no response on the Hyperterminal connection.

Cause

After RLC replacements there was no communication with the library.

 



 

Solution

Ordered New Serial Cable:

Use Part Number # 4108289-01.

Alternative Part Number # 410828902 CABLE ASSY,20 FT,RDC,CCITT
 

References

<NOTE:1366515.1> - SL500/SL3000/SL8500 - Process for One Time Password, Administration Account

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback