![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1549331.1 : False Service LED Indicators on Sun Blade X6220 Server Module
In this Document
Applies to:Sun Blade X6220 Server Module - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. In rare cases Blades are flagging spurious errors on functioning HDDs and on non existant HDDs. SymptomsHDD(x)/SERVICE glow on functioning drives and on non existant drives.
ChangesHost reboot/reset HDDx/FAIL event CauseIn rare cases a host reset/reboot is causing the wrong HDD LED state ILOM will glow HDD(x+1)/SERVICE instead of HDD(x)/SERVICE when HDD(x)/FAIL gets asserted SolutionWorkaround: - Ignore the ILOM HDD LED state - Use the related operating system features for HDD health monitoring Attachments This solution has no attachment |
||||||||||||||||||
|