Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1549331.1
Update Date:2018-03-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1549331.1 :   False Service LED Indicators on Sun Blade X6220 Server Module  


Related Items
  • Sun Blade X6220 Server Module
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Blades>SN-x64: BLADE
  •  




In this Document
Symptoms
Changes
Cause
Solution


Applies to:

Sun Blade X6220 Server Module - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
In rare cases Blades are flagging spurious errors on functioning HDDs and on non existant HDDs.

Symptoms

HDD(x)/SERVICE glow on functioning drives and on non existant drives.

 

Changes

Host reboot/reset

HDDx/FAIL event

Cause

In rare cases a host reset/reboot is causing the wrong HDD LED state

ILOM will glow HDD(x+1)/SERVICE instead of HDD(x)/SERVICE when HDD(x)/FAIL gets asserted

Solution

Workaround:

- Ignore the ILOM HDD LED state

- Use the related operating system features for HDD health monitoring