Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1548118.1
Update Date:2017-07-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  1548118.1 :   FDR HCA's support in XgOS 3.8.2  


Related Items
  • Oracle Fabric Interconnect F1-15
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-6938752721>

Applies to:

Oracle Fabric Interconnect F1-15 - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Unable to bring up new FDR HCA's in IB environment while running XgOS 3.8.2.  This issue is fixed in XgOS versions above 3.8.2 (Example, fixed in 3.9.0, 3.9.2, and all 4.x XgOS versions).

Cause

Issue was caused by IB subnet manager timing.
 

 

Solution

Modified opensm.opts  to include 'fdr10 0' in Fabric Interconnect when logged into the Fabric Interconnect as user 'root'.  This file is located at:

/opt/xsigo/xsigos/xsigos-<ver>-XGOS/ofed/etc/opensm.opts




References

<BUG:16606417> - OPENSM 3.3.13 GOES INTO BAD STATE WHEN 7 OR MORE HOSTS WITH FDR HCAS ARE UP

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback