Solution Type Problem Resolution Sure Solution 1547972.1 : Class: fault.memory.intel.dimm.none Message ID: SPX86-8001-ME
The system will not boot showing no output. ILOM snapshot may show either "Memory : BIOS : Configuration Error : MRC error Major 0xE8" or an ereport for "fault.memory.intel.dimm.none" implying it has no working memory. In this Document
Created from <SR 3-6973958771> Applies to:Sun Fire X4170 M2 Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. Applies to X4170 M2 and X4270 M2 SymptomsILOM turns on the system fault LED, and the system will not boot showing no output. ILOM snapshot may show either "Memory : BIOS : Configuration Error : MRC error Major 0xE8" or an ereport for "fault.memory.intel.dimm.none" implying it has no working memory. ILOM FMA output may show output like: Fault class : fault.memory.intel.dimm.none
FRU : /SYS/MB (Part Number: 511-1213-07) (Serial Number: 0328MSL-1233BA3HCT) Description : Memory DIMMs are not populated. Response : BIOS forwards error telemetry to the SP for diagnosis and logging in ILOM event log. Impact : The entire memory subsystem is unusable and there is no video output. Action : The administrator should review the ILOM event log for additional information pertaining to this diagnosis. Please refer to the Details section of the Knowledge Article for additional information.
CauseAfter reset /SYS, SP doesn't set the right status of SMBUS_mux pin. So BIOS SolutionWorkaround: Perform a complete power cycle of the system by removing the AC power cords for several minutes, then re-applying AC power and rebooting the system. Repeat if first attempt does not succeed. Attachments This solution has no attachment |
||||||||||||||||
|