![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1546937.1 : T10000C - FSC37C1 Reported From Tape Drive
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:StorageTek T10000C Tape Drive - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsDrive failed with FSC 37A1, FSC37A1 FRU: MICROCODE CONF: 100% ChangesT10000C - this problem can occur if a tape written in a higher density is put into a T1000C drive with code that does not recognize that higher density. CauseIn this scenario, a tape was created in T10000D drive in the lab and was sent to customer by mistake. Then this tape was read by T10000C and failed. SolutionInform customer to put this tape aside. For T10000C, code 1.57.308 due out first of May 2013 shall have the fix. Attachments This solution has no attachment |
||||||||||||||||||||||
|