Solution Type  Problem Resolution Sure

Solution  1546412.1 :   SC initiating soft host system shutdown due to fault at MB.P0.V_CORE on SunFire V210,V240,V215,V245 Servers  


Related Items
  • Sun Fire V245 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-V2x0
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7066920301>

Applies to:

Sun Fire V245 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Customer reports that the system is crashing due to voltage issues.

Cause

There is an issue on the MB sensor (in this case, MB.P0.V_CORE) that caused the system shutdown

It can be seen in the following explorer output or by running the ALOM command "showlogs -v"
 
Apr 15 10:10:16 : 00070002: "SC initiating soft host system shutdown due to fault at MB.P0.V_CORE."


##### sysconfig/scadm/scadm-loghistory.out #####

Apr 13 01:16:26 : 00070002: "VOLTAGE_SENSOR @ MB.P0.V_CORE has exceeded low warning threshold."
Apr 13 01:16:27 : 00070002: "VOLTAGE_SENSOR @ MB.P0.V_CORE is within normal range."
Apr 13 01:16:30 : 00070002: "VOLTAGE_SENSOR @ MB.P0.V_CORE has exceeded low warning threshold."
Apr 13 01:16:34 : 00070002: "VOLTAGE_SENSOR @ MB.P0.V_CORE is within normal range."
Apr 13 01:17:43 : 00070002: "VOLTAGE_SENSOR @ MB.P0.V_CORE has exceeded low warning threshold."
Apr 13 01:17:46 : 00070002: "VOLTAGE_SENSOR @ MB.P0.V_CORE is within normal range."
Apr 13 01:20:23 : 00070002: "VOLTAGE_SENSOR @ MB.P0.V_CORE has exceeded low warning threshold."
Apr 13 01:20:24 : 00070002: "VOLTAGE_SENSOR @ MB.P0.V_CORE is within normal range."
Apr 13 01:20:29 : 00070002: "VOLTAGE_SENSOR @ MB.P0.V_CORE has exceeded low warning threshold."
 

Solution

This problem was fixed after replacing the motherboard