Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1546380.1
Update Date:2017-08-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  1546380.1 :   T10000 A/B/C - FSC5535 - The File Reel Moved Unexpectedly During The Time When The Cartridge Leader Should be Stationary  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7063969011>

Applies to:

Sun StorageTek T10000A Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
StorageTek T10000C Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

FSC: 5535 The file reel moved unexpectedly during the time when the cartridge leader should be stationary (ears seated).

Cartridge will not load into drive.

Media has the leader inside the cartridge.

FSC5535

Cause

Media xxxxx has the leader inside the cartridge
 

 

Solution

Check media xxxxx for the leader inside the cartridge.

If this occurs, ask a Field Engineer through the Service Request to repair the leader using the clutch tool.


 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback