Solution Type  Problem Resolution Sure

Solution  1545354.1 :   SL500 - Drive Targeting Errors - Drives "Inop" in SLConsole, Result Code 5501  


Related Items
  • HP LTO6 Tape Drive
  •  
  • Sun StorageTek SL500 Modular Library System
  •  
  • HP LTO4 Tape Drive
  •  
  • HP LTO5 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  


All the drives are showing Inop in the SLConsole and the EventLog are showing targeting errors in all the drives. However, the robot is fine.

In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-6845877301>

Applies to:

Sun StorageTek SL500 Modular Library System - Version All Versions and later
HP LTO4 Tape Drive - Version All Versions and later
HP LTO5 Tape Drive - Version All Versions and later
HP LTO6 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

All four drives are shown as inoperative on SL500.

The EventLog will show targeting errors on the robot like Result Code:5501 in all the drives. However, the robot is fine.  RC5501, 5501

2013-02-22 17:53:30 Drive_Bay3(0,2,1,9)
5501 - (4X)
Director - auditResponse() : cmo_user_audit: Failed target calibration for (LMRC) 0,2,1,9, result code=5501
(Errors Started - 2013-02-13 13:45:24 Errors Stopped - 2013-02-22 17:53:30)


2013-02-22 17:52:01 Drive_Bay4(0,2,2,9)
5501 - (4X)
Director - auditResponse() : cmo_user_audit: Failed target calibration for (LMRC) 0,2,2,9, result code=5501
(Errors Started - 2013-02-13 13:45:52 Errors Stopped - 2013-02-22 17:52:01)

2013-02-21 18:22:58 Drive_Bay2(0,1,2,9)
5501 - (3X)
Director - auditResponse() : cmo_user_audit: Failed target calibration for (LMRC) 0,1,2,9, result code=5501
(Errors Started - 2013-02-13 13:44:55 Errors Stopped - 2013-02-21 18:22:58)

2013-02-21 18:22:31 Drive_Bay1(0,1,1,9)
5501 - (3X)
Director - auditResponse() : cmo_user_audit: Failed target calibration for (LMRC) 0,1,1,9, result code=5501
(Errors Started - 2013-02-13 13:44:28 Errors Stopped - 2013-02-21 18:22:31)

 

 

Changes

 This issue will unlikely take place in a working library.  It will happen in a new install.

The customer installed the SL500 themselves following the instructions.  However the drive bezels were not delivered by mistake.

Cause

The drives have no bezels.
 
We have determined that there are no drive bezels in the SL500 nor did they ship with the library.
 

Solution

Install bezels on the drives or replace broken bezels.

Refer to the following documents:

- HP LTO - Part Number for HP LTO Bezel Used in L20/L40/L80 Library [ID 1393035.1]

- CRU Replacement of Target Bezel for HP LTO Drive in SL500 Library:ATR:1373177.1:0 [ID 1373177.1]

References

<NOTE:1373177.1> - CRU Replacement of Target Bezel for HP LTO Drive in SL500 Library:ATR:1373177.1:0
<NOTE:1393035.1> - HP LTO - Part Number for HP LTO Bezel Used in L20/L40/L80 Library

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback