![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1545354.1 : SL500 - Drive Targeting Errors - Drives "Inop" in SLConsole, Result Code 5501
All the drives are showing Inop in the SLConsole and the EventLog are showing targeting errors in all the drives. However, the robot is fine. In this Document
Created from <SR 3-6845877301> Applies to:Sun StorageTek SL500 Modular Library System - Version All Versions and laterHP LTO4 Tape Drive - Version All Versions and later HP LTO5 Tape Drive - Version All Versions and later HP LTO6 Tape Drive - Version All Versions and later Information in this document applies to any platform. SymptomsAll four drives are shown as inoperative on SL500. The EventLog will show targeting errors on the robot like Result Code:5501 in all the drives. However, the robot is fine. RC5501, 5501 2013-02-22 17:53:30 Drive_Bay3(0,2,1,9)
ChangesThis issue will unlikely take place in a working library. It will happen in a new install. The customer installed the SL500 themselves following the instructions. However the drive bezels were not delivered by mistake. CauseThe drives have no bezels. SolutionInstall bezels on the drives or replace broken bezels. Refer to the following documents: - HP LTO - Part Number for HP LTO Bezel Used in L20/L40/L80 Library [ID 1393035.1] - CRU Replacement of Target Bezel for HP LTO Drive in SL500 Library:ATR:1373177.1:0 [ID 1373177.1] References<NOTE:1373177.1> - CRU Replacement of Target Bezel for HP LTO Drive in SL500 Library:ATR:1373177.1:0<NOTE:1393035.1> - HP LTO - Part Number for HP LTO Bezel Used in L20/L40/L80 Library Attachments This solution has no attachment |
||||||||||||||||||||
|